Call 08048615474 90% Response Rate

Send Enquiry

our range

Testing Unit

Providing you the best range of pt testing unit and ct testing unit with effective & timely delivery.

PT Testing Unit

PT Testing Unit
Get Best Quote
Rs 5,000  / PiecePrice on Request

Product Brochure

Frequency45 Hz to 55 Hz or 55 Hz to 65 Hz
Insulation ResistanceGreater than 20 Mohms at 500 V DC
Dielectric Strength2 kV RMS for 1 minute
WeightApprox. 8Kg
Resolution0.1 Vac
Operating Temperature0 to 55 Deg C
Measuring Time7 seconds, irrespective of signal level and error range
Operating Voltage3 to 110 V AC, 0.5 VA
Auxiliary Supply110 V / 240 V. AC +- 20%, 50 / 60 Hz, 60 VA
Size180x320x450mm
Accuracy+-0.5% of RDG +- 1% of range
PhaseSingle phase
HumidityUp-to 95% RH
ModelPTU
OutputsRS 232 C port & Parallel port (data in ASCII format)
Storage Temperature- 20 to 70 Deg C
Keeping in sync with the latest market norms and policies, we are indulged in providing a high-quality range of PT Testing Unit.

Description:
It compares & reads the error due to imbalance in signals of test PT with reference PT and applies necessary proportional signal to nullify the error. Input is displayed in percentage or actual value, and phase error in centiradians or minutes.

On separate key commands the error readings with date, time,% input & burden are sent either to a PC through RS 232 C port or to a printer connected to parallel port, in order to have report in "view format".

Other Details:

  • Micro processor controlled
  • Self zero check and calibration check
  • Digital display of %input, ratio error and phase error.
  • Programmable voltage input
  • Manual and auto ranging modes
  • RS 232 C port and parallel port for printing
  • Built in real time clock
  • Parameter entry through keyboard

View Complete details

Yes! I am Interested Request a call back

CT Testing Unit

CT Testing Unit
Get Best Quote
Rs 5,000  / PiecePrice on Request

Product Brochure

PhaseSingle Phase
Frequency45 Hz to 55 Hz or 55 Hz to 65 Hz.
Size180x320x450mm
WeightApprox.8Kg
Storage Temperature-20 Deg C to 70 DegC
Insulation ResistanceGreater than 20 Mohms at 500V. DC.
ModelCTU
HumidityUp-to 95% RH.
Resolution0.05% of range
Measuring Time7 seconds irrespective of signal level and error range.
Operating Temperature0 to 55 DegC
OutputsRS 232 C port & Parallel port (data in ASCII format).
Auxiliary Supply+/- 0.5% of reading +/-1 % of range
Dielectric Strength2 kV RMS for 1 minute
Operating Current1 A / 5 A, 0.5 VA
Other Details:
  • Microprocessor controlled
  • Self zero check and calibration check
  • Digital display of %input, ratio error and phase error
  • Manual and auto ranging modes
  • Test 5 A and 1 A CT with either 1 A or 5 A reference CT
  • RS 232 C port and parallel port for printing
  • Built in real time clock
  • Parameter entry through keyboard